CFM Range Hood ZN-36

Téléchargements : 0 Taille : 675 kb    Fabricant : CFM  
Catégorie : Ventilateurs

reinforced concrete, plasterboard, etc.). If the screws and screw anchors are provided with the product, check that they are suitable for the type of wall on which the hood is to be fixed. • FIXING THE DECORATIVE TELESCOPIC FLUE Arrange the electrical power supply within the dimensions of the decorative flue. Prepare the air exhaust opening. Adjust the width of the support bracket of the upper flue (Fig.3). Then fix it to the ceiling using the screws A (Fig.3) in such a way that it is in line wi

CFM Range Hood PN-I

Téléchargements : 6 Taille : 806 kb    Fabricant : CFM  
Catégorie : Ventilateurs

IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Take care when using cleaning agents or detergents. Suitable for use in household cooking area WARNING - To reduce the risk of fire or electric shock, do not use this fan with any Solid-State Speed Control Device. CAUTION - To reduce risk of fire and to properly exhaust air, be sure to du

CFM Range Hood MC-I-6090

Téléchargements : 1 Taille : 919 kb    Fabricant : CFM  
Catégorie : Ventilateurs

• FIXING THE DECORATIVE TELESCOPIC FLUE Arrange the electrical power supply within the dimensions of the decorative flue. If your appliance is to be installed in the ducting version or in the version with external motor, prepare the air exhaust opening. Adjust the width of the support bracket of the upper flue (Fig.4).Then fix it to the ceiling using the screws A (Fig.4) in such a way that it is in line with your hood and respecting the distance from the ceiling indicated in Fig.3. Connect the f

CFM PEF30

Téléchargements : 6 Taille : 36 kb    Fabricant : CFM  
Catégorie : Ventilateurs

6. Secure fan assembly to shutter using screws and washers. 7. Ensure that fasteners are snug. Do not over tighten to avoid stripping nylon inserts. M MMO OOD DDE EEL LL S SSE EEF FF- --3 330 00 C CCo oon nnt tte een nnt tts ss: :: Pre-assembled guard mount fan, shutter, shutter mounting hardware kit, package of mounting screws. To mount shutter to fan assembly: 1. Shutter mounting hardware kit includes: 4 rubber vibration isolators, 8 rubber inserts, 8 screws (#8-32 x 11/2”) and 8 rubberized wa

CFM PEF10

Téléchargements : 26 Taille : 36 kb    Fabricant : CFM  
Catégorie : Ventilateurs

6. Lag shutter to wall through mounting holes in shutter gusset, using appropriate fasteners (by others). 7. Rotate fan impeller by hand, ensuring that it is unobstructed and rotates freely. 8. Make electrical connections to fan junction box. M MMO OOD DDE EEL LL P PPE EEF FF- --1 110 00 T TTH HHR RRO OOU UUG GGH HH P PPE EEF FF- --3 330 00 1. Cut wall opening size .” larger than fan venturi opening. 2. From inside of building / room, center fan panel assembly over wall opening. Fan must be posi

CFM M-0710

Téléchargements : 4 Taille : 36 kb    Fabricant : CFM  
Catégorie : Ventilateurs

Cut square wall opening size .” larger than fan blade diameter. 2. From inside of building / room, center fan assembly over wall opening. Fan must be positioned so that junction box is located at bottom and shutter is level and square, with shutter blades opening upwards. 3. Lag fan to wall through mounting holes in shutter gusset, using appropriate fasteners (by others). 4. Rotate fan impeller by hand, ensuring that it is unobstructed and rotates freely. 5. Make electrical connections to fan ju

CFM HW-120M

Téléchargements : 1 Taille : 364 kb    Fabricant : CFM  
Catégorie : Ventilateurs

Is ignition cable firmly plugged into module? Is green ground wire firmly attached to mounting screw and GND terminal on module? Is pilot burner ignition cable in good condition (not brittle, burnt, or cracked)? Ensure ground strap is the closest metal to the igniter/sensor rod (electrode) to prevent the spark from shorting out to other metal parts (pilot screen, pilot shield, etc.). Ignition cable must not touch metal surfaces or current carrying wires. Is there a 1/8” gap between ground strap

CFM HRV-60

Téléchargements : 2 Taille : 417 kb    Fabricant : CFM  
Catégorie : Ventilateurs

INSIDE BASE E B A FAN PANEL DIMENSION G DAMPER (OPTIONAL) CURB DIMENSIONS IN INCHES* PERFORMANCE RATING WT (LBS) MAX MTR MINIMUM MAXIMUM MAXIMUM CFM MODEL A B D E G LESS MTR FRAME HP MODEL CFM CFM WITH FILTERS HRV-24 30 54 x 64 41.5 39 25.5 324 145T 1/4 - 1 HRV-24 800 6,700 4,861 HRV-30 36 60 x 76 41.5 45 25.5 365 145T 1/3 - 11/2 HRV-30 800 11,800 11,800 HRV-36 42 72 x 82 45.5 51 27.5 410 145T 1/3 - 2 HRV-36 1,800 15,376 13,889 HRV-42 48 80 x 89 45.5 57 27.5 503 184T 1/2 - 3 HRV-42 3,300 22,296

CFM HRV-54

Téléchargements : 2 Taille : 417 kb    Fabricant : CFM  
Catégorie : Ventilateurs

Blade pitch angles shall be factory set. C. Axial impeller hub shall be designed to incorporate a split taper bushing, and be keyed directly to drive shaft. 4 44. ..0 00 F FFA AAN NN M MMO OOT TTO OOR RR A AAN NND DD D DDR RRI IIV VVE EE A. Motor shall be TEFC industrial duty and conform to NEMA standards. B. Motor shall be of voltage, horsepower, RPM and enclosure as indicated on the fan schedule. C. Fan sheaves shall be cast iron and appropriately sized and aligned. D. Fan belts shall be stati

CFM HRV-48

Téléchargements : 14 Taille : 417 kb    Fabricant : CFM  
Catégorie : Ventilateurs

INSIDE BASE E B A FAN PANEL DIMENSION G DAMPER (OPTIONAL) CURB DIMENSIONS IN INCHES* PERFORMANCE RATING WT (LBS) MAX MTR MINIMUM MAXIMUM MAXIMUM CFM MODEL A B D E G LESS MTR FRAME HP MODEL CFM CFM WITH FILTERS HRV-24 30 54 x 64 41.5 39 25.5 324 145T 1/4 - 1 HRV-24 800 6,700 4,861 HRV-30 36 60 x 76 41.5 45 25.5 365 145T 1/3 - 11/2 HRV-30 800 11,800 11,800 HRV-36 42 72 x 82 45.5 51 27.5 410 145T 1/3 - 2 HRV-36 1,800 15,376 13,889 HRV-42 48 80 x 89 45.5 57 27.5 503 184T 1/2 - 3 HRV-42 3,300 22,296